Guides / Tier II Reporting in Tennessee

Tier II Chemical Reporting in Tennessee: Who Files & How

⏰ OSHA HazCom deadline — November 20, 2026: employers must update their workplace labels, written HazCom program, and employee training to the new GHS format by then. Check your program free — 2-minute self-audit →
Updated September 2026

Short answer: if your Tennessee facility stores a hazardous chemical at or above its EPCRA reporting threshold — generally 10,000 pounds, or as low as 500 pounds for an Extremely Hazardous Substance — you must file an annual Tier II chemical-inventory report by March 1, covering the prior calendar year. It goes to your State Emergency Response Commission (SERC), your Local Emergency Planning Committee (LEPC), and your local fire department. In Tennessee you file electronically through E-Plan, for the State Emergency Response Commission within the Tennessee Emergency Management Authority (TEMA). The hardest part is compiling an accurate inventory with quantities — which is exactly what SDSentry ($24 per location per month) keeps current for you year-round. Here is how Tier II works in Tennessee.

Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.

Could you produce the sheet for every product on your shelf? Paste your product list and get each manufacturer’s current safety data sheet as one printable binder index — free, no signup. Build my SDS binder — free →

What Tier II is (and isn't)

Tier II is the annual chemical-inventory report required under Section 312 of the Emergency Planning and Community Right-to-Know Act (EPCRA). Its purpose is to tell fire departments and emergency planners what hazardous chemicals are stored at your facility, in what quantities, and where, so responders know what they are walking into. It is a separate obligation from OSHA Hazard Communication — the same chemicals on your shelves, but a different law and a different audience. Meeting your HazCom duties does not satisfy Tier II, and vice versa.

Who has to file in Tennessee

The trigger is federal and applies the same way in Tennessee as everywhere else. You must file Tier II if any hazardous chemical for which you are required to keep a safety data sheet is present at your facility at or above its reporting threshold at any point during the year:

Quantities are based on the maximum amount present at any one time, aggregated across the facility. A small clinic or shelter often stays under these limits, but bulk propane or diesel tanks, stored fuel, pool and spa chemicals, fertilizer, or a large supply of a single disinfectant can push you over — and EHS thresholds are low enough that a modest amount of the wrong chemical can trigger a report.

Where Tennessee facilities submit

EPCRA sends every Tier II report to three places: your State Emergency Response Commission (SERC), your Local Emergency Planning Committee (LEPC), and your local fire department.

Tennessee's State Emergency Response Commission (SERC) sits within the Tennessee Emergency Management Authority (TEMA) — the agency's name changed from “Agency” to “Authority” in July 2026, so you may see both on state pages.

Tennessee requires Tier II reports to be filed electronically through E-Plan (erplan.net), using its online Tier II filing section. Filing in E-Plan meets the SERC requirement only: TEMA's FAQ tells facilities to contact their LEPC to confirm whether it wants a paper copy, which you can print from E-Plan, and the same applies to your local fire department. Start from TEMA's Tier II chemical information page.

State systems and instructions can change year to year, so confirm current details with TEMA and the Tennessee SERC before you file.

The deadline

TEMA's FAQ: “Tier II reports are due by March 1st of each year” — for the previous calendar year, the same as the federal date. Build in time before the deadline to gather quantities and have your preparer review them, because the last week of February is a poor time to discover your inventory list is out of date.

Are there Tennessee state fees?

The State of Tennessee does not charge a fee, but filing is not free. TEMA's FAQ: “E-plan charges $25.00 per facility to submit a Tier II report. The charge is paid directly to E-Plan, and the State of Tennessee has no additional charges.” Because E-Plan is the required system, budget $25 per facility each year.

What to have ready before you file

The report itself is mostly a structured list. What slows people down is assembling accurate underlying data. Before you start, have on hand:

If you keep a current SDS library and a per-location inventory with quantities throughout the year, the February scramble largely disappears. See our guide on building a chemical inventory from scratch for a starting point.

How SDSentry helps

SDSentry tracks quantity and unit per item in your per-location inventory, flags items over a threshold you set, and exports an EPCRA Tier II CSV so your preparer is not rebuilding the inventory by hand each February. It keeps a current SDS on file for every product, which is where most of the hazard and storage details on the report come from. It will not submit the report for you — you still file through E-Plan — but it turns the worst part, compiling and maintaining the data, into a download. Pair it with our HazCom compliance checklist so your OSHA and EPCRA obligations stay covered at the same time.

Track inventory for Tier II — free trial

Educational information only, not legal or compliance advice. Tier II thresholds, deadlines, submission methods, and any state fees change, and Tennessee's specific process is set by the state. Verify your obligations with TEMA and the Tennessee SERC, and with EPA's EPCRA resources at epa.gov/epcra, before you file — and consult a qualified professional for your situation.

Start with the chemical list
A HazCom program starts from a list of the hazardous chemicals at your site. Download the free chemical inventory list template as a CSV for Excel or Google Sheets, or as a printable PDF. Free, no signup.
Get the free chemical inventory template →

📋 Could you produce the sheet for every product on your shelf?
Paste the products you keep on site and get each manufacturer’s current safety data sheet laid out as one printable binder index — the thing an inspector asks to see. Free, no signup, nothing emailed to you.
Build my SDS binder — free →
Just one product? Free SDS search. Want to know where your site stands against 29 CFR 1910.1200? 2-minute HazCom self-audit. No signup for either.

Frequently asked questions

Who do I send my Tier II report to in Tennessee?

Tennessee requires Tier II reports to be filed electronically through E-Plan, for the State Emergency Response Commission within the Tennessee Emergency Management Authority (TEMA). E-Plan filing satisfies the SERC; contact your LEPC and local fire department to confirm whether they want a copy, which you can print from E-Plan.

When is the Tier II deadline in Tennessee?

March 1 each year, covering the prior calendar year. TEMA's FAQ states that Tier II reports are due by March 1st of each year.

What are the Tier II reporting thresholds?

You report if a hazardous chemical that requires a safety data sheet is on site at or above 10,000 pounds at any time during the year, or at or above 500 pounds — or the Threshold Planning Quantity, whichever is lower — for an Extremely Hazardous Substance. Quantities are the maximum amount present at any one time.

Is there a Tennessee state fee for Tier II?

The State of Tennessee charges nothing, but E-Plan, the state's required filing system, charges $25.00 per facility per report, paid directly to E-Plan.