Tier II Chemical Reporting in South Dakota: Who Files & How
Short answer: if your South Dakota facility stores a hazardous chemical at or above its EPCRA reporting threshold — generally 10,000 pounds, or as low as 500 pounds for an Extremely Hazardous Substance — you must file an annual Tier II chemical-inventory report by March 1, covering the prior calendar year. It goes to your State Emergency Response Commission (SERC), your Local Emergency Planning Committee (LEPC), and your local fire department. In South Dakota you file online with the Department of Agriculture and Natural Resources (DANR), send copies to your fire department and LEPC, and pay a fee by April 1. The hardest part is compiling an accurate inventory with quantities — which is exactly what SDSentry ($24 per location per month) keeps current for you year-round. Here is how Tier II works in South Dakota.
Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.
What Tier II is (and isn't)
Tier II is the annual chemical-inventory report required under Section 312 of the Emergency Planning and Community Right-to-Know Act (EPCRA). Its purpose is to tell fire departments and emergency planners what hazardous chemicals are stored at your facility, in what quantities, and where, so responders know what they are walking into. It is a separate obligation from OSHA Hazard Communication — the same chemicals on your shelves, but a different law and a different audience. Meeting your HazCom duties does not satisfy Tier II, and vice versa.
Who has to file in South Dakota
The trigger is federal and applies the same way in South Dakota as everywhere else. You must file Tier II if any hazardous chemical for which you are required to keep a safety data sheet is present at your facility at or above its reporting threshold at any point during the year:
- 10,000 lbs for most hazardous chemicals (those that require an SDS).
- 500 lbs — or the chemical's Threshold Planning Quantity, whichever is lower — for Extremely Hazardous Substances (EHSs) on EPA's list.
Quantities are based on the maximum amount present at any one time, aggregated across the facility. A small clinic or shelter often stays under these limits, but bulk propane or diesel tanks, stored fuel, pool and spa chemicals, fertilizer, or a large supply of a single disinfectant can push you over — and EHS thresholds are low enough that a modest amount of the wrong chemical can trigger a report.
Where South Dakota facilities submit
EPCRA sends every Tier II report to three places: your State Emergency Response Commission (SERC), your Local Emergency Planning Committee (LEPC), and your local fire department.
South Dakota's Tier II program is run by the Department of Agriculture and Natural Resources (DANR), which links the SD Online Tier II reporting system from its SARA Title III page. DANR's reporting guide: “By March 1, copies of Tier II reports must be submitted to ALL of the following: 1) State of South Dakota/SERC (When your sign a report on-line, it is automatically submitted to the State of South Dakota/SERC). 2) Local Fire Department … 3) Local Emergency Planning Committee (LEPC).”
So the state copy is automatic, and you print the report from the system and send the fire department and LEPC copies yourself; the reporting website links their mail and email addresses. Start from DANR's SARA Title III page.
State systems and instructions can change year to year, so confirm current details with SD DANR before you file.
The deadline
DANR: “Tier II Reports are due March 1 but the fee is not due until April 1. Payments postmarked after April 1 are late.”
Are there South Dakota state fees?
Yes, per facility by the number of reportable chemicals (SDCL 1-50-8 (checked Oct 2026)): $0 if you store no reportable chemical but report voluntarily; $50 for 1–3 chemicals; $100 for 4–9; $200 for 10–18; and $300 for 19 or more. After April 1, “A $15 penalty applies to fees of $150 or less and a 10% penalty applies to fees of $200 or more.” There is no fee for Section 311 reports.
What to have ready before you file
The report itself is mostly a structured list. What slows people down is assembling accurate underlying data. Before you start, have on hand:
- A complete chemical inventory for the location, with the product name and chemical identity for each item.
- The maximum quantity on site during the year and the average daily quantity, with units.
- Storage details — container type, pressure, temperature, and the specific location or building.
- Hazard information from each product's safety data sheet.
- Facility identifiers, emergency contacts, and (where required) latitude and longitude.
If you keep a current SDS library and a per-location inventory with quantities throughout the year, the February scramble largely disappears. See our guide on building a chemical inventory from scratch for a starting point.
How SDSentry helps
SDSentry tracks quantity and unit per item in your per-location inventory, flags items over a threshold you set, and exports an EPCRA Tier II CSV so your preparer is not rebuilding the inventory by hand each February. It keeps a current SDS on file for every product, which is where most of the hazard and storage details on the report come from. It will not submit the report for you — you still file through South Dakota's online Tier II system — but it turns the worst part, compiling and maintaining the data, into a download. Pair it with our HazCom compliance checklist so your OSHA and EPCRA obligations stay covered at the same time.
Track inventory for Tier II — free trial
Frequently asked questions
Who do I send my Tier II report to in South Dakota?
Sign and submit your report in South Dakota's online Tier II system, which automatically submits it to the State/SERC. By March 1 you must also send printed copies to your local fire department and your LEPC.
When is the Tier II deadline in South Dakota?
Reports are due March 1; the fee is due April 1.
What are the Tier II reporting thresholds?
You report if a hazardous chemical that requires a safety data sheet is on site at or above 10,000 pounds at any time during the year, or at or above 500 pounds — or the Threshold Planning Quantity, whichever is lower — for an Extremely Hazardous Substance. Quantities are the maximum amount present at any one time.
Is there a South Dakota state fee for Tier II?
Yes. DANR charges per facility by chemical count: $50 for 1 to 3 reportable chemicals, $100 for 4 to 9, $200 for 10 to 18 and $300 for 19 or more, with a $15 or 10% late penalty after April 1.