Tier II Chemical Reporting in Idaho: Who Files & How
Short answer: if your Idaho facility stores a hazardous chemical at or above its EPCRA reporting threshold — generally 10,000 pounds, or as low as 500 pounds for an Extremely Hazardous Substance — you must file an annual Tier II chemical-inventory report by March 1, covering the prior calendar year. It goes to your State Emergency Response Commission (SERC), your Local Emergency Planning Committee (LEPC), and your local fire department. In Idaho you email a Tier2 Submit file to the Idaho Office of Emergency Management (IOEM) and send your own copies to the LEPC and fire department. The hardest part is compiling an accurate inventory with quantities — which is exactly what SDSentry ($24 per location per month) keeps current for you year-round. Here is how Tier II works in Idaho.
Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.
What Tier II is (and isn't)
Tier II is the annual chemical-inventory report required under Section 312 of the Emergency Planning and Community Right-to-Know Act (EPCRA). Its purpose is to tell fire departments and emergency planners what hazardous chemicals are stored at your facility, in what quantities, and where, so responders know what they are walking into. It is a separate obligation from OSHA Hazard Communication — the same chemicals on your shelves, but a different law and a different audience. Meeting your HazCom duties does not satisfy Tier II, and vice versa.
Who has to file in Idaho
The trigger is federal and applies the same way in Idaho as everywhere else. You must file Tier II if any hazardous chemical for which you are required to keep a safety data sheet is present at your facility at or above its reporting threshold at any point during the year:
- 10,000 lbs for most hazardous chemicals (those that require an SDS).
- 500 lbs — or the chemical's Threshold Planning Quantity, whichever is lower — for Extremely Hazardous Substances (EHSs) on EPA's list.
Quantities are based on the maximum amount present at any one time, aggregated across the facility. A small clinic or shelter often stays under these limits, but bulk propane or diesel tanks, stored fuel, pool and spa chemicals, fertilizer, or a large supply of a single disinfectant can push you over — and EHS thresholds are low enough that a modest amount of the wrong chemical can trigger a report.
Where Idaho facilities submit
EPCRA sends every Tier II report to three places: your State Emergency Response Commission (SERC), your Local Emergency Planning Committee (LEPC), and your local fire department.
Idaho has no separate commission: under Idaho Code §39-7104, “The military division shall have the powers and duties of a state emergency response commission,” acting through the Idaho Office of Emergency Management (IOEM). IOEM: “Idaho requires use of the Tier2 Submit software or Tier II form (where applicable),” and “Completed Tier II Reports may be submitted to: tier2@imd.idaho.gov.”
Paper is allowed only for small filers. IOEM's letter of instruction for the 2025 reporting year: “All facilities reporting five (5) or more chemicals/products must use the electronic submission process. Facilities below this threshold may choose to file using the paper form.” Either way, the locals are on you: “Reports must also be submitted to the facility’s LEPC & local Fire Department.” Start from IOEM's Tier II reporting page.
State systems and instructions can change year to year, so confirm current details with IOEM (tier2@imd.idaho.gov) before you file.
The deadline
IOEM: “The deadline for 2025 submissions is March 1, 2026,” and its letter adds that all reports, “EITHER ELECTRONIC OR HARD-COPY,” must be received by that date. The same March 1 date applies every year.
Are there Idaho state fees?
We found no Tier II filing fee on IOEM's pages or in its letters of instruction. Don't confuse this with the Idaho DEQ “Tier II operating permit” fee, which is an air-quality permit and unrelated to EPCRA. Because silence is not a “no fee” statement, confirm with IOEM.
What to have ready before you file
The report itself is mostly a structured list. What slows people down is assembling accurate underlying data. Before you start, have on hand:
- A complete chemical inventory for the location, with the product name and chemical identity for each item.
- The maximum quantity on site during the year and the average daily quantity, with units.
- Storage details — container type, pressure, temperature, and the specific location or building.
- Hazard information from each product's safety data sheet.
- Facility identifiers, emergency contacts, and (where required) latitude and longitude.
If you keep a current SDS library and a per-location inventory with quantities throughout the year, the February scramble largely disappears. See our guide on building a chemical inventory from scratch for a starting point.
How SDSentry helps
SDSentry tracks quantity and unit per item in your per-location inventory, flags items over a threshold you set, and exports an EPCRA Tier II CSV so your preparer is not rebuilding the inventory by hand each February. It keeps a current SDS on file for every product, which is where most of the hazard and storage details on the report come from. It will not submit the report for you — you still file through Tier2 Submit — but it turns the worst part, compiling and maintaining the data, into a download. Pair it with our HazCom compliance checklist so your OSHA and EPCRA obligations stay covered at the same time.
Track inventory for Tier II — free trial
Frequently asked questions
Who do I send my Tier II report to in Idaho?
Email your Tier2 Submit file to the Idaho Office of Emergency Management at tier2@imd.idaho.gov; facilities reporting five or more chemicals must file electronically, while smaller facilities may mail a paper form. You must also submit the report to your LEPC and local fire department.
When is the Tier II deadline in Idaho?
March 1 each year; IOEM says reports, electronic or hard copy, must be received by March 1.
What are the Tier II reporting thresholds?
You report if a hazardous chemical that requires a safety data sheet is on site at or above 10,000 pounds at any time during the year, or at or above 500 pounds — or the Threshold Planning Quantity, whichever is lower — for an Extremely Hazardous Substance. Quantities are the maximum amount present at any one time.
Is there a Idaho state fee for Tier II?
We found no Tier II filing fee in IOEM's materials, but no explicit no-fee statement either. The Idaho DEQ 'Tier II operating permit' fee is an unrelated air-quality permit fee.