Chemical Hygiene Plan Template and Checklist (Printable)
How to use it: print this page (the button hides the site navigation) and fill it in for your lab or department. The sections follow the eight elements OSHA requires in a Chemical Hygiene Plan, in the order of 29 CFR 1910.1450(e)(3), followed by the other parts of the standard the plan has to connect to: training (f), medical consultation (g), SDSs and labels (h) and records (j). It is an outline of what the regulation requires, not a finished plan and not legal advice; OSHA’s non-mandatory Appendix A to 1910.1450 has more guidance.
Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.
School / college / department: ______________________ Labs covered: ______________________
Chemical Hygiene Officer: ______________________ Plan date: __________ Next annual review: __________
General requirements (1910.1450(e)(1), (e)(2), (e)(4))
- The plan is written, specific to these labs, and capable of protecting employees from the health hazards of the chemicals used here and of keeping exposures below OSHA’s limits ((e)(1)).
- It is readily available to employees and their representatives, and to OSHA (or the State Plan agency) on request ((e)(2)). Location:
- It is reviewed and evaluated for effectiveness at least annually and updated as necessary ((e)(4)). Last review: __________
1. Standard operating procedures ((e)(3)(i))
- Written SOPs for safety and health in lab work with hazardous chemicals: general lab rules, chemical handling and transfer, dispensing and diluting acids, heating and flames, spills, waste and end-of-day shutdown.
- Procedure-specific SOPs for higher-hazard work (for example: diluting concentrated hydrochloric or glacial acetic acid, burning magnesium, handling silver nitrate).
- Emergency procedures: eyewash and safety shower use, fire, evacuation, who to call.
2. Criteria for control measures ((e)(3)(ii))
- How the lab decides on engineering controls (fume hood, ventilation), PPE (goggles, face shield, gloves, lab coat or apron) and hygiene practices (no food or drink, hand washing) for each chemical or procedure.
- Particular attention to chemicals known to be extremely hazardous, identified from Section 2 of each SDS.
- Written PPE hazard assessment certified under 29 CFR 1910.132(d); see the PPE hazard assessment.
3. Fume hoods and protective equipment ((e)(3)(iii))
- A stated requirement that fume hoods and other protective equipment function properly.
- Specific measures: who checks hood airflow and how often, how a failed hood is tagged out, eyewash and safety shower checks (see eyewash requirements), fire extinguishers suited to the chemicals (including Class D or dry sand for reactive metals).
4. Information and training ((e)(3)(iv), (f))
- Training at initial assignment and before new exposure situations; refresher frequency set by the employer: __________ ((f)(2)).
- Employees informed of: the standard and its appendices; where the CHP is; PELs or recommended limits; signs and symptoms of exposure; where reference material and SDSs are ((f)(3)).
- Training covers detecting releases, the physical and health hazards of the chemicals in the work area, protective measures and emergency procedures, and the details of this CHP ((f)(4)).
- Training records: who, when, what. See HazCom training requirements.
5. Activities that need prior approval ((e)(3)(v))
- List of operations, procedures or activities that need approval from the employer or a designee before they start (for example: new demonstrations, work with particularly hazardous substances, unattended reactions, work alone after hours).
- Who approves:
6. Medical consultation and examinations ((e)(3)(vi), (g))
- Employees get an opportunity for medical attention when they develop symptoms, when monitoring shows routine exposure above an action level or PEL with medical surveillance requirements, and after a spill, leak, explosion or other likely hazardous exposure ((g)(1)).
- By or under a licensed physician, at no cost, without loss of pay, at a reasonable time and place ((g)(2)). Provider:
- The physician gets the chemical identity (the SDS), the exposure conditions and the symptoms ((g)(3)); a written opinion is obtained ((g)(4)).
7. Responsible people and the Chemical Hygiene Officer ((e)(3)(vii))
- People responsible for implementing the plan named, including the Chemical Hygiene Officer: an employee qualified by training or experience to give technical guidance on the plan.
- A Chemical Hygiene Committee, if appropriate:
- Stockroom, teacher and lab-technician responsibilities listed (ordering, receiving, inventory, SDS filing, waste).
8. Particularly hazardous substances ((e)(3)(viii))
- Select carcinogens, reproductive toxins and substances with a high degree of acute toxicity identified from the SDSs (for example, the reproductive-toxicity classifications on the silver nitrate and potassium permanganate sheets, the carcinogenicity class on phenolphthalein indicator, and formalin).
- Where appropriate: a designated area ((A)); containment devices such as fume hoods or glove boxes ((B)); procedures for safe removal of contaminated waste ((C)); decontamination procedures ((D)).
SDSs, labels and chemicals made in the lab ((h))
- Labels on incoming containers left intact ((h)(1)(i)).
- SDSs received with shipments kept and readily accessible to lab employees ((h)(1)(ii)), during each workshift (1910.1200(b)(3)(ii)). Where:
- Chemical inventory matches the SDS collection; see the school science lab chemical inventory and SDS binder.
- Rule for labelling secondary containers and student solutions (the free GHS label maker prints them).
- Chemicals made in the lab: hazard determined if composition known; unknown byproducts treated as hazardous; anything sent outside the lab handled under HazCom ((h)(2)).
Exposure monitoring, respirators and records ((d), (i), (j))
- Monitoring where there is reason to believe exposure routinely exceeds an action level or PEL; results to employees in writing within 15 working days ((d)).
- Respirators, if ever needed to stay below PELs, provided at no cost under 1910.134 ((i)).
- Monitoring and medical records kept per employee and handled under 29 CFR 1910.20 ((j)).
Where SDSentry fits: SDSentry holds the safety data sheets and the chemical inventory for each location, so the sheets your CHP points to are current and reachable on a phone or tablet, and prints GHS labels. It does not write safety data sheets, and it is not a chemical hygiene plan service: the plan, the Chemical Hygiene Officer, the SOPs and the medical consultation arrangements are yours.
Frequently asked questions
What are the required elements of a chemical hygiene plan?
OSHA 29 CFR 1910.1450(e)(3) requires standard operating procedures; criteria for control measures; measures ensuring fume hoods and protective equipment work; information and training; activities requiring prior approval; medical consultation and examinations; designation of responsible personnel including a Chemical Hygiene Officer; and extra protection for particularly hazardous substances.
How often must a chemical hygiene plan be reviewed?
At least annually. 29 CFR 1910.1450(e)(4) requires the employer to review and evaluate the plan's effectiveness at least annually and update it as necessary.
Is there an OSHA chemical hygiene plan template?
OSHA does not issue a fill-in template, but Appendix A to 29 CFR 1910.1450 is non-mandatory guidance for developing the plan. This checklist follows the required elements in the order of paragraph (e)(3).
Does SDSentry write chemical hygiene plans?
No. SDSentry keeps the safety data sheets and chemical inventory the plan relies on and prints GHS labels; the plan itself, the Chemical Hygiene Officer and the procedures are the employer's.
Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →
SDSentry keeps your SDS library, GHS labels and HazCom training records in one place — $24 per location a month, or $199 a year, with unlimited users.
Unlimited users and no SDS cap. On an annual plan that is less than any paid SDS tool we compared.
Start 7-day free trial Compare SDS software prices →