10% Formalin SDS: What the Safety Data Sheet Says
📄 Get the SDS: Fisher Scientific 10% buffered formalin SDS (PDF)
Short answer: Fisher Scientific’s SDS for Formalin, Buffered, 10% (4.0% formaldehyde, revised 18 December 2025, written to the 2024 HazCom standard) classifies it as Carcinogenicity Category 1A, Serious Eye Damage 1, Skin Sensitization 1, Germ Cell Mutagenicity 2, STOT single exposure 1, skin irritant and combustible liquid, signal word Danger. Formaldehyde also has its own OSHA standard, 29 CFR 1910.1048, with a 0.75 ppm PEL.
Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.
What the 10% formalin SDS covers
We read Fisher Scientific’s sheet for Formalin, Buffered, 10% (Phosphate Buffer/Certified), catalog SF100, revision 4, 18 December 2025, checked October 10, 2026:
- Classification (Section 2): Flammable liquids Category 4; Skin Corrosion/Irritation Category 2; Serious Eye Damage Category 1; Skin Sensitization Category 1; Germ Cell Mutagenicity Category 2; Carcinogenicity Category 1A; STOT single exposure Category 1 (respiratory system, CNS, optic nerve).
- Hazard statements: "Combustible liquid", "Causes skin irritation", "May cause an allergic skin reaction", "Causes serious eye damage", "Suspected of causing genetic defects", "May cause cancer", "Causes damage to organs".
- Pictograms: under GHS these classes carry the health hazard, corrosion and exclamation mark pictograms.
- Composition (Section 3): water 92–94%; formaldehyde (CAS 50-00-0) 4.0%; methyl alcohol 1.0–2.0%; sodium phosphate buffer salts.
- Flash point (Section 9): 81 °C (177.8 °F).
- Exposure limits (Section 8): formaldehyde OSHA PEL 0.75 ppm TWA and 2 ppm STEL; ACGIH TLV 0.1 ppm TWA and 0.3 ppm STEL; NIOSH REL 0.016 ppm TWA and 0.1 ppm ceiling.
The OSHA formaldehyde standard applies on top of HazCom
29 CFR 1910.1048 "applies to all occupational exposures to formaldehyde", including formaldehyde solutions such as formalin (osha.gov: 29 CFR 1910.1048). In outline:
- Limits: 0.75 ppm as an 8-hour TWA and 2 ppm as a 15-minute STEL ((c)); the action level is 0.5 ppm as an 8-hour TWA ((b)).
- Exposure monitoring ((d)) unless objective data show formaldehyde cannot reach the action level or STEL under foreseeable conditions.
- Medical surveillance ((l)) for employees exposed at or above the action level or above the STEL.
- Training ((n)) for employees assigned to workplaces with formaldehyde exposure, unless objective data show exposure stays below 0.1 ppm; and hazard communication under 1910.1200 ((m)).
Read the standard itself for the details that apply to your clinic; this is a summary, not legal advice.
PPE and handling the sheet calls for
- The sheet says use only under a chemical fume hood, with eyewash stations and safety showers close to the workstation.
- Eyes: protective eyeglasses or chemical safety goggles (29 CFR 1910.133). Skin: appropriate protective gloves and clothing.
- Respiratory: a NIOSH-approved respirator if exposure limits are exceeded or irritation is experienced.
First aid (Section 4)
- Eyes: rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes; immediate medical attention is required.
- Skin: wash off immediately with plenty of water for at least 15 minutes; get medical attention.
- Inhaled: remove to fresh air; give oxygen if breathing is difficult; immediate medical attention is required. Swallowed: do NOT induce vomiting; call a physician or poison control center immediately. In the United States, Poison Control is 1-800-222-1222.
Storage
Keep containers tightly closed in a dry, cool, well-ventilated place, away from heat, sparks and flame; "Store locked up" (Sections 2 and 7). Prefilled biopsy specimen containers are formalin too: they belong on the inventory, and a jar you fill yourself needs a label naming formalin and its hazards.
Where to get the right formalin SDS
- The sheet we read: Fisher Scientific 10% buffered formalin SDS (PDF), checked October 10, 2026. Formalin from your reference laboratory or another supplier has its own sheet; keep the one for the product you have.
- Your supplier must provide the SDS with the first shipment (29 CFR 1910.1200(g)(6)–(7)); veterinary distributors usually also post it on the product page. Or search for a formalin SDS with our free SDS search.
Where it fits in a veterinary clinic HazCom program
Formalin belongs in your clinic’s SDS binder or digital SDS library, on your chemical inventory, and in the HazCom training you give every veterinarian, technician, assistant, kennel attendant and front-desk hire before they handle it. If you decant or dilute it, label the new container: the free GHS label maker prints secondary-container labels from the hazard classes above. See OSHA requirements for veterinary clinics, the veterinary clinic SDS binder list and the printable veterinary HazCom checklist.
Frequently asked questions
Is 10% formalin a carcinogen?
Yes. Fisher Scientific's SDS for 10% buffered formalin (revised 18 December 2025) classifies it as Carcinogenicity Category 1A, along with Serious Eye Damage 1, Skin Sensitization 1, Germ Cell Mutagenicity 2 and STOT SE 1, with the signal word Danger.
How much formaldehyde is in 10% formalin?
The SDS lists 4.0% formaldehyde, with 1-2% methyl alcohol, in water with phosphate buffer salts. "10% formalin" means a 10% dilution of saturated (about 37-40%) formaldehyde solution.
What is the OSHA limit for formaldehyde?
Under 29 CFR 1910.1048 the PEL is 0.75 ppm as an 8-hour TWA and 2 ppm as a 15-minute STEL, with an action level of 0.5 ppm.
Does the OSHA formaldehyde standard apply to a veterinary clinic using biopsy jars?
The standard applies to all occupational exposures to formaldehyde, including formalin. Monitoring can be avoided only where objective data show exposure cannot reach the action level or STEL, and training is required unless objective data show exposure below 0.1 ppm.
Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →
SDSentry keeps your SDS library, GHS labels and HazCom training records in one place — $24 per location a month, or $199 a year, with unlimited users.
Unlimited users and no SDS cap. On an annual plan that is less than any paid SDS tool we compared.