Magnesium Ribbon SDS: What the Safety Data Sheet Says
📄 Get the SDS: Flinn magnesium SDS (sds_468)
Short answer: Flinn Scientific’s SDS for magnesium (turnings or ribbon, revised 21 March 2014) classifies it as a Flammable Solid Category 1, "Flammable solid", signal word Danger, {FLAME} pictogram. It is a water-reactive metal: avoid contact with acids or water, and fight a magnesium fire with a Class D extinguisher or dry sand, never water. In a school, that matters most for the ribbon-burning demonstration.
Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.
What the magnesium SDS covers
We read Flinn’s sheet sds_468, checked October 10, 2026:
- Classification (Section 2): Flammable solids Category 1 (H228). "Keep away from heat, sparks, open flames, and hot surfaces. No smoking."
- Composition and properties: magnesium (CAS 7439-95-4); silvery-white metal turnings or ribbon; insoluble in water, soluble in acids; melting point 651 °C.
- Fire fighting (Section 5): "Water reactive metal; avoid contact with acids or water." "Use a Class D or dry sand as a fire extinguisher. Avoid water contact, violent reaction with water."
- Incompatibilities (Section 10): water, acids, acid chlorides, strong oxidizers, halogens and chlorinated solvents.
- Transport: UN1869, Magnesium, Hazard Class 4.1 flammable solid.
Powdered magnesium has a separate, more hazardous Flinn sheet (sds_468.1); keep the sheet that matches the form you stock.
PPE and handling
- Gloves, protective clothing and eye protection; wash hands after handling (Section 8).
- Burning magnesium gives off an intense white light; set the viewing rules for demonstrations in your lab procedures. Have the Class D extinguisher or dry sand at hand before the demonstration, and keep water away.
- Spills: remove ignition sources and water, sweep up, and place in a sealed container (Section 6).
First aid (Section 4)
- Eyes: rinse cautiously with water for several minutes; remove contact lenses if easy; continue rinsing. Skin: wash with plenty of water.
- Swallowed: rinse mouth; call a poison center or physician if you feel unwell. In the United States, Poison Control is 1-800-222-1222.
Storage
Flinn’s suggested pattern is Inorganic #1: with metals and metal hydrides, in a sealed metal can, away from acids, oxidizers and water. Do not store it beside hydrochloric or acetic acid; see chemical storage compatibility.
Where to get the current magnesium ribbon SDS
- The sheet we read: Flinn magnesium SDS (sds_468), checked October 10, 2026. Other suppliers’ ribbon sheets may classify it differently; keep the sheet from the company you buy from.
- Your supplier must provide the SDS with the first shipment (29 CFR 1910.1200(g)(6)–(7)); school science suppliers such as Flinn, and lab distributors such as Fisher, also publish their sheets free online. Or search for a magnesium ribbon SDS with our free SDS search.
Where it fits in a school or college lab program
Magnesium ribbon belongs on your stockroom chemical inventory, and its SDS belongs in the binder or digital SDS library that teachers, lab technicians and employed teaching assistants can reach during every work shift (29 CFR 1910.1450(h)(1)(ii) and 1910.1200(b)(3)(ii)). Keep the manufacturer’s label on the stock bottle intact (1910.1450(h)(1)(i)). The Lab Standard’s label rule covers incoming containers; for student dropper bottles and solutions you make up, your Chemical Hygiene Plan sets the rule, and labelling them is the safe default: the free GHS label maker prints labels from the hazard classes above. See the OSHA Lab Standard for schools and colleges, the school science lab chemical inventory and SDS binder and the printable chemical hygiene plan checklist.
Frequently asked questions
Is magnesium ribbon flammable?
Yes. Flinn Scientific's SDS classifies magnesium turnings and ribbon as a Flammable Solid Category 1, signal word Danger.
How do you put out a magnesium fire?
Flinn's SDS says to use a Class D extinguisher or dry sand and to avoid water, which reacts violently with burning magnesium.
What should magnesium not be stored with?
Water, acids, acid chlorides, strong oxidizers, halogens and chlorinated solvents. Flinn suggests Inorganic #1, with metals and metal hydrides.
Does a school need an SDS for magnesium ribbon?
Yes. Magnesium is a hazardous chemical under HazCom (a flammable solid), and laboratories must keep the SDSs received with incoming shipments readily accessible to lab employees (29 CFR 1910.1200(b)(3)(ii) and 1910.1450(h)(1)(ii)).
Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →
SDSentry keeps your SDS library, GHS labels and HazCom training records in one place — $24 per location a month, or $199 a year, with unlimited users.
Unlimited users and no SDS cap. On an annual plan that is less than any paid SDS tool we compared.
Start 7-day free trial Compare SDS software prices →