OSHA Requirements for Breweries, Wineries and Distilleries
Short answer: a brewery, winery or distillery with employees falls under the same general industry standards as any plant. Five come up in almost every one: Hazard Communication (29 CFR 1910.1200) for the caustics, acids and sanitizers; carbon dioxide exposure limits (OSHA PEL 5000 ppm; NIOSH IDLH 40,000 ppm); permit-required confined spaces (1910.146), because tanks are named in the definition; eyewash and drench facilities where corrosives are used (1910.151(c)); and a written PPE hazard assessment (1910.132). This page summarises the regulation text; it is not legal advice.
Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.
1. Hazard Communication: the cleaning chemicals (29 CFR 1910.1200)
CIP and sanitation chemicals are where most of a craft producer’s chemical hazard sits: caustic at pH 13 or more, nitric and phosphoric acid cleaners, peracetic acid, and acid or iodine sanitizers. HazCom requires:
- a written hazard communication program with a list of the hazardous chemicals on site ((e)(1)); see written HazCom program requirements;
- a current SDS for each one, "readily accessible during each work shift" to employees in their work areas ((g)(8));
- labels on shipped containers and workplace labels on secondary containers such as buckets, spray bottles and CIP make-up tanks ((f)); the free GHS label maker prints them; and
- training at initial assignment and whenever a new chemical hazard is introduced ((h)); see HazCom training requirements.
Three exemptions matter in this industry, and they are narrower than they sound:
- EPA-registered sanitizers such as Star San, Saniclean PAA Pro and iodophor carry a pesticide label, and 1910.1200(b)(5)(i) does not require a separate HazCom label on them. The SDS and training duties still apply, and the EPA label can be stricter than the SDS: see the iodophor sanitizer SDS.
- Packaged beer, wine and spirits for nonindustrial use that are subject to the Federal Alcohol Administration Act’s labeling rules do not need HazCom labels ((b)(5)(iv)).
- Taproom and tasting room service: the standard does not apply to "food or alcoholic beverages which are sold, used, or prepared in a retail establishment (such as a grocery store, restaurant, or drinking place)" ((b)(6)(vi)).
None of these covers the chemicals that clean and sanitize the equipment, the CO2 and nitrogen cylinders, the chiller glycol or bulk ethanol in a still house.
2. Carbon dioxide: exposure limits and where it collects
Fermentation makes carbon dioxide, and breweries also buy it for carbonation, purging and draft systems. The limits, from OSHA Table Z-1 (29 CFR 1910.1000) and the NIOSH Pocket Guide:
- OSHA PEL: 5000 ppm (9000 mg/m³), 8-hour time-weighted average.
- NIOSH REL: 5000 ppm TWA and 30,000 ppm short-term (15 minutes).
- NIOSH IDLH: 40,000 ppm.
- Symptoms NIOSH lists: headache, dizziness, restlessness, breathing difficulty, sweating, increased heart rate and blood pressure, and at high levels coma, asphyxia and convulsions; frostbite from liquid CO2 or dry ice.
Supplier SDSs give CO2 a relative vapour density of about 1.5 (air = 1), so it settles in tanks, pits, cellars, walk-in coolers and below-grade rooms (see the carbon dioxide SDS). Fixed CO2 monitors in fermentation rooms and cold rooms, and ventilation that pulls from low points, are common controls; nitrogen and argon used for purging or blanketing displace oxygen the same way (see the nitrogen SDS).
3. Tanks and permit-required confined spaces (29 CFR 1910.146)
OSHA defines a confined space as a space large enough to bodily enter and work in, with limited or restricted means of entry or exit, and not designed for continuous occupancy; the definition’s own examples are "tanks, vessels, silos, storage bins, hoppers, vaults, and pits" ((b)). Fermenters, brite tanks, wine tanks, mash tuns, grain silos and spent-grain hoppers can all meet it. It becomes a permit-required confined space if it has one or more of these:
- a hazardous atmosphere or the potential for one, which includes oxygen below 19.5% or above 23.5%, and any substance above its OSHA PEL, such as CO2 above 5000 ppm;
- material that could engulf an entrant (grain in a silo or hopper);
- an internal shape that could trap or asphyxiate an entrant (inwardly converging walls or a floor sloping to a smaller cross-section, such as a conical tank bottom); or
- any other recognized serious safety or health hazard (for example, agitators, hot water or chemicals fed into the tank).
What the standard then requires:
- Evaluate the workplace to determine which spaces are permit spaces ((c)(1)).
- Inform employees with danger signs or an equally effective means; "DANGER—PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER" satisfies it ((c)(2)).
- If employees will not enter, take effective measures to prevent entry ((c)(3)). Cleaning a tank entirely by CIP and spray ball, without anyone entering, is one way to do that.
- If employees will enter, a written permit space program ((c)(4)), entry permits signed by the entry supervisor and posted at the entry ((e)), attendants, and rescue and emergency services evaluated in advance ((k)).
- Before entry, test the atmosphere: "test first for oxygen, then for combustible gases and vapors, and then for toxic gases and vapors" ((d)(5)(iii)).
- Where the only hazard is an atmospheric one that continuous forced-air ventilation alone controls, and monitoring data support that, the alternate procedures in (c)(5) can apply.
- When a contractor enters your tanks, tell them the spaces are permit spaces, what makes them so and what precautions you use, and coordinate the entry ((c)(8)).
The official text is at osha.gov: 29 CFR 1910.146, with a decision flow chart in Appendix A and sample permits in Appendix D.
4. Eyewash and drench: 29 CFR 1910.151(c)
"Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use." Caustic CIP cleaners, nitric and phosphoric acid cleaners, peracetic acid, Star San concentrate and potassium metabisulfite powder are all classified as causing severe skin burns or serious eye damage on their SDSs, so the places where they are poured, dosed or mixed are where the eyewash belongs. The PAA and Saniclean sheets call for at least 30 minutes of flushing. See eyewash station requirements and the ANSI Z358.1 consensus standard.
5. PPE and the written hazard assessment: 29 CFR 1910.132
- PPE must be provided, used and maintained wherever chemical or process hazards could injure the body through absorption, inhalation or contact ((a)).
- The employer must assess the workplace for hazards that call for PPE, select PPE that protects against them, tell each affected employee, and make sure it fits ((d)(1)).
- The assessment must be certified in writing: the workplace evaluated, the person certifying, the date, and a statement that it is a certification of hazard assessment ((d)(2)). See the PPE hazard assessment.
- In a brewery the assessment usually covers hot caustic and acid CIP (goggles and face shield, chemical gloves, apron), sanitizer make-up, KMBS and dry-ice handling, hot liquor and wort, keg handling, and the respirator question for any task where an exposure assessment says one is needed (29 CFR 1910.134).
6. Other standards that commonly apply
- Lockout/tagout (29 CFR 1910.147) for servicing pumps, mills, augers, centrifuges, packaging lines and tank agitators.
- Powered industrial trucks (29 CFR 1910.178) for forklift operator training.
- Flammable liquids (29 CFR 1910.106) for distilleries and bulk ethanol; see the ethanol SDS and flammable storage cabinet requirements.
- Process Safety Management (29 CFR 1910.119) can apply to ammonia refrigeration systems above the threshold quantity; glycol chillers are covered on the propylene glycol SDS page.
7. OSHA and the brewing industry
OSHA has no brewery-specific standard. In November 2022 OSHA announced an alliance with the New York State Department of Labor, the New York State Brewers Association, the Brewers Association and the Master Brewers Association of the Americas to give New York’s brewing industry information, guidance and training resources; the announcement is now in OSHA’s archive and says the agreement expired on November 9, 2024. Where an OSHA-approved State Plan covers private employers (22 State Plans do), the state’s rules apply and must be at least as effective as OSHA’s (OSHA State Plans).
Brewery, winery and distillery SDS sheets
What the safety data sheets for the chemicals in a typical cellar say, each checked against the manufacturer’s current sheet:
- Star San SDS (and Saniclean)
- PBW SDS (powdered brewery wash)
- Caustic CIP cleaner SDS
- Brewery acid cleaner SDS (nitric/phosphoric)
- Peracetic acid sanitizer SDS
- Iodophor sanitizer SDS
- Potassium metabisulfite SDS
- Ethanol SDS
- Propylene glycol SDS
- Carbon dioxide SDS
- Nitrogen SDS
- Sodium hydroxide SDS
- Hydrogen peroxide SDS
- Quat sanitizer SDS
- Denatured alcohol SDS
Where SDSentry fits: SDSentry holds the safety data sheets and the chemical inventory for each location, so cellar, packaging and production staff can reach the current sheet on a phone during any shift, and prints GHS labels for buckets, spray bottles and CIP tanks. It does not write safety data sheets, and it does not run your confined space program, gas monitoring or PPE assessment: those stay with you.
Next: the printable brewery SDS binder and chemical checklist. The official text of each standard is on eCFR and osha.gov.
Frequently asked questions
What OSHA standards apply to breweries?
Breweries are general industry workplaces. The standards that come up most are Hazard Communication (29 CFR 1910.1200), permit-required confined spaces (1910.146), eyewash and drench facilities for corrosives (1910.151(c)), PPE and the written hazard assessment (1910.132), lockout/tagout (1910.147), powered industrial trucks (1910.178) and the Table Z-1 limit for carbon dioxide.
What is the OSHA limit for CO2 in a brewery?
OSHA's PEL for carbon dioxide is 5000 ppm as an 8-hour TWA. NIOSH recommends 5000 ppm TWA and 30,000 ppm short-term, and lists 40,000 ppm as immediately dangerous to life or health.
Is a fermentation tank a confined space?
It can be. OSHA's definition names tanks and vessels as examples of spaces with limited entry. A tank becomes a permit-required confined space if it can hold a hazardous atmosphere, such as CO2 above its PEL or oxygen below 19.5%, or has another serious hazard; the employer must evaluate each one under 29 CFR 1910.146(c)(1).
Do beer and wine need SDSs?
Packaged beer, wine and spirits subject to federal alcohol labeling rules do not need HazCom labels (1910.1200(b)(5)(iv)), and alcoholic beverages sold or served in a retail establishment such as a taproom are excluded ((b)(6)(vi)). The cleaning chemicals, gases and bulk ethanol in production still need SDSs.
Does a brewery need an eyewash station?
Where employees' eyes or bodies may be exposed to injurious corrosive materials, 29 CFR 1910.151(c) requires quick-drench or flushing facilities within the work area. Caustic and acid CIP cleaners and acid or peracetic sanitizer concentrates are classified as corrosive on their SDSs.
Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →
SDSentry keeps your SDS library, GHS labels and HazCom training records in one place — $24 per location a month, or $199 a year, with unlimited users.
Unlimited users and no SDS cap. On an annual plan that is less than any paid SDS tool we compared.
Start 7-day free trial Compare SDS software prices →