Guides / OSHA for Breweries and Wineries

OSHA Requirements for Breweries, Wineries and Distilleries

⏰ OSHA HazCom 2024 deadline — November 20, 2026 (substances): employers must, as necessary, update workplace labels, the written HazCom program and employee training for newly identified hazards. For mixtures the date is May 19, 2028 (29 CFR 1910.1200(j)). Check your program free — 2-minute self-audit →
Updated October 2026

Short answer: a brewery, winery or distillery with employees falls under the same general industry standards as any plant. Five come up in almost every one: Hazard Communication (29 CFR 1910.1200) for the caustics, acids and sanitizers; carbon dioxide exposure limits (OSHA PEL 5000 ppm; NIOSH IDLH 40,000 ppm); permit-required confined spaces (1910.146), because tanks are named in the definition; eyewash and drench facilities where corrosives are used (1910.151(c)); and a written PPE hazard assessment (1910.132). This page summarises the regulation text; it is not legal advice.

Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.

Could you produce the sheet for every product on your shelf? Paste your product list and get each product’s safety data sheet as one printable binder index — free, no signup. Build my SDS binder — free →

1. Hazard Communication: the cleaning chemicals (29 CFR 1910.1200)

CIP and sanitation chemicals are where most of a craft producer’s chemical hazard sits: caustic at pH 13 or more, nitric and phosphoric acid cleaners, peracetic acid, and acid or iodine sanitizers. HazCom requires:

Three exemptions matter in this industry, and they are narrower than they sound:

None of these covers the chemicals that clean and sanitize the equipment, the CO2 and nitrogen cylinders, the chiller glycol or bulk ethanol in a still house.

2. Carbon dioxide: exposure limits and where it collects

Fermentation makes carbon dioxide, and breweries also buy it for carbonation, purging and draft systems. The limits, from OSHA Table Z-1 (29 CFR 1910.1000) and the NIOSH Pocket Guide:

Supplier SDSs give CO2 a relative vapour density of about 1.5 (air = 1), so it settles in tanks, pits, cellars, walk-in coolers and below-grade rooms (see the carbon dioxide SDS). Fixed CO2 monitors in fermentation rooms and cold rooms, and ventilation that pulls from low points, are common controls; nitrogen and argon used for purging or blanketing displace oxygen the same way (see the nitrogen SDS).

3. Tanks and permit-required confined spaces (29 CFR 1910.146)

OSHA defines a confined space as a space large enough to bodily enter and work in, with limited or restricted means of entry or exit, and not designed for continuous occupancy; the definition’s own examples are "tanks, vessels, silos, storage bins, hoppers, vaults, and pits" ((b)). Fermenters, brite tanks, wine tanks, mash tuns, grain silos and spent-grain hoppers can all meet it. It becomes a permit-required confined space if it has one or more of these:

  1. a hazardous atmosphere or the potential for one, which includes oxygen below 19.5% or above 23.5%, and any substance above its OSHA PEL, such as CO2 above 5000 ppm;
  2. material that could engulf an entrant (grain in a silo or hopper);
  3. an internal shape that could trap or asphyxiate an entrant (inwardly converging walls or a floor sloping to a smaller cross-section, such as a conical tank bottom); or
  4. any other recognized serious safety or health hazard (for example, agitators, hot water or chemicals fed into the tank).

What the standard then requires:

The official text is at osha.gov: 29 CFR 1910.146, with a decision flow chart in Appendix A and sample permits in Appendix D.

4. Eyewash and drench: 29 CFR 1910.151(c)

"Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use." Caustic CIP cleaners, nitric and phosphoric acid cleaners, peracetic acid, Star San concentrate and potassium metabisulfite powder are all classified as causing severe skin burns or serious eye damage on their SDSs, so the places where they are poured, dosed or mixed are where the eyewash belongs. The PAA and Saniclean sheets call for at least 30 minutes of flushing. See eyewash station requirements and the ANSI Z358.1 consensus standard.

5. PPE and the written hazard assessment: 29 CFR 1910.132

6. Other standards that commonly apply

7. OSHA and the brewing industry

OSHA has no brewery-specific standard. In November 2022 OSHA announced an alliance with the New York State Department of Labor, the New York State Brewers Association, the Brewers Association and the Master Brewers Association of the Americas to give New York’s brewing industry information, guidance and training resources; the announcement is now in OSHA’s archive and says the agreement expired on November 9, 2024. Where an OSHA-approved State Plan covers private employers (22 State Plans do), the state’s rules apply and must be at least as effective as OSHA’s (OSHA State Plans).

Brewery, winery and distillery SDS sheets

What the safety data sheets for the chemicals in a typical cellar say, each checked against the manufacturer’s current sheet:

Where SDSentry fits: SDSentry holds the safety data sheets and the chemical inventory for each location, so cellar, packaging and production staff can reach the current sheet on a phone during any shift, and prints GHS labels for buckets, spray bottles and CIP tanks. It does not write safety data sheets, and it does not run your confined space program, gas monitoring or PPE assessment: those stay with you.

Next: the printable brewery SDS binder and chemical checklist. The official text of each standard is on eCFR and osha.gov.

Educational information only, not legal or compliance advice. Requirements can vary by product, use and jurisdiction — verify at osha.gov/hazcom and 29 CFR 1910.1200, or consult a qualified professional.

Start with the chemical list
A HazCom program starts from a list of the hazardous chemicals at your site. Download the free chemical inventory list template as a CSV for Excel or Google Sheets, or as a printable PDF. Free, no signup.
Get the free chemical inventory template →

📋 Could you produce the sheet for every product on your shelf?
Paste the products you keep on site and get each product’s safety data sheet laid out as one printable binder index — the thing an inspector asks to see. Free, no signup, nothing emailed to you.
Build my SDS binder — free →
Just one product? Free SDS search. Want to know where your site stands against 29 CFR 1910.1200? 2-minute HazCom self-audit. No signup for either.

Frequently asked questions

What OSHA standards apply to breweries?

Breweries are general industry workplaces. The standards that come up most are Hazard Communication (29 CFR 1910.1200), permit-required confined spaces (1910.146), eyewash and drench facilities for corrosives (1910.151(c)), PPE and the written hazard assessment (1910.132), lockout/tagout (1910.147), powered industrial trucks (1910.178) and the Table Z-1 limit for carbon dioxide.

What is the OSHA limit for CO2 in a brewery?

OSHA's PEL for carbon dioxide is 5000 ppm as an 8-hour TWA. NIOSH recommends 5000 ppm TWA and 30,000 ppm short-term, and lists 40,000 ppm as immediately dangerous to life or health.

Is a fermentation tank a confined space?

It can be. OSHA's definition names tanks and vessels as examples of spaces with limited entry. A tank becomes a permit-required confined space if it can hold a hazardous atmosphere, such as CO2 above its PEL or oxygen below 19.5%, or has another serious hazard; the employer must evaluate each one under 29 CFR 1910.146(c)(1).

Do beer and wine need SDSs?

Packaged beer, wine and spirits subject to federal alcohol labeling rules do not need HazCom labels (1910.1200(b)(5)(iv)), and alcoholic beverages sold or served in a retail establishment such as a taproom are excluded ((b)(6)(vi)). The cleaning chemicals, gases and bulk ethanol in production still need SDSs.

Does a brewery need an eyewash station?

Where employees' eyes or bodies may be exposed to injurious corrosive materials, 29 CFR 1910.151(c) requires quick-drench or flushing facilities within the work area. Caustic and acid CIP cleaners and acid or peracetic sanitizer concentrates are classified as corrosive on their SDSs.


Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →

SDSentry keeps your SDS library, GHS labels and HazCom training records in one place — $24 per location a month, or $199 a year, with unlimited users.

Unlimited users and no SDS cap. On an annual plan that is less than any paid SDS tool we compared.

Start 7-day free trial Compare SDS software prices →