Guides / Propylene Glycol SDS

Propylene Glycol SDS: What a USP Propylene Glycol Sheet Says

⏰ OSHA HazCom 2024 deadline — November 20, 2026 (substances): employers must, as necessary, update workplace labels, the written HazCom program and employee training for newly identified hazards. For mixtures the date is May 19, 2028 (29 CFR 1910.1200(j)). Check your program free — 2-minute self-audit →
Updated October 2026

Short answer: BASF’s SDS for 1,2-Propylene Glycol USP (version 6.1, revised June 25, 2025), written to the 2024 HazCom standard, says there is "no need for classification according to GHS criteria" and the product "does not require a hazard warning label". Its flash point is 104 °C (closed cup). Glycol sold for chillers is often an inhibited blend from another supplier with its own sheet, so check what is in your tank.

Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.

Could you produce the sheet for every product on your shelf? Paste your product list and get each product’s safety data sheet as one printable binder index — free, no signup. Build my SDS binder — free →

What the propylene glycol SDS covers

We read BASF’s US sheet, checked October 20, 2026:

Chiller glycol: check which product is in the tank

Brewery and winery chillers usually circulate a propylene glycol and water mix, often bought as a pre-blended, inhibited heat-transfer fluid. Corrosion inhibitors and dyes can change the classification, so the USP sheet above covers only pure propylene glycol: keep the sheet from the company that sold your blend. Automotive antifreeze is usually ethylene glycol, a different chemical with a different SDS (see antifreeze SDS). Where a refrigeration system uses ammonia rather than glycol, that is a separate hazard with its own OSHA requirements and is outside this page.

A chemical that is not hazardous under HazCom does not need an SDS on file, but many breweries keep this one so the binder matches the inventory and so a glycol leak or spill can be answered quickly.

PPE and handling the sheet calls for

First aid (Section 4)

Storage

Keep the container tightly closed and dry, in a cool place no warmer than 40 °C (104 °F), protected from air, humidity and light, and away from oxidizers. See chemical storage compatibility.

Where to get the current propylene glycol SDS

Where it fits in a brewery, winery or distillery HazCom program

Your chiller glycol belongs on your chemical inventory, and its SDS belongs where cellar, packaging and production staff can reach it during every shift (29 CFR 1910.1200(g)(8)). Train people on it before they use it, and again when a new hazard comes in, such as a new supplier or formula (1910.1200(h)(1)). Buckets, spray bottles and CIP make-up tanks filled from the drum need a workplace label unless they are only for the immediate use of the person who filled them: the free GHS label maker prints them from the hazard classes above (see secondary container labeling). Keep acids, caustics and oxidizers apart (chemical storage compatibility), and see the OSHA requirements for breweries and wineries and the printable brewery SDS binder checklist.

Educational information only, not legal or compliance advice. Requirements can vary by product, use and jurisdiction — verify at osha.gov/hazcom and 29 CFR 1910.1200, or consult a qualified professional.

Find the current Propylene Glycol SDS
Search for Propylene Glycol in the free SDS search and open a manufacturer’s safety data sheet you can view or print. Different makers and strengths have different sheets, so check it matches the product you use. Free, no signup.
Search the Propylene Glycol SDS — free →

📋 Could you produce the sheet for every product on your shelf?
Paste the products you keep on site and get each product’s safety data sheet laid out as one printable binder index — the thing an inspector asks to see. Free, no signup, nothing emailed to you.
Build my SDS binder — free →
Just one product? Free SDS search. Want to know where your site stands against 29 CFR 1910.1200? 2-minute HazCom self-audit. No signup for either.

Frequently asked questions

Is propylene glycol hazardous under OSHA?

BASF's SDS for 1,2-Propylene Glycol USP (June 2025) says it needs no classification under GHS criteria and requires no hazard warning label. Inhibited glycol blends sold for chillers can differ, so check the sheet for the exact product.

What is the flash point of propylene glycol?

The BASF sheet gives 104 C (219 F), closed cup, and describes it as not readily ignited.

Does propylene glycol have an OSHA PEL?

No. The BASF SDS says no substance-specific occupational exposure limits are known.

Do I need an SDS for chiller glycol?

HazCom requires SDSs for hazardous chemicals. Pure USP propylene glycol is not classified, but an inhibited blend may be, so keep the sheet from the company that sold your glycol.


Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →

SDSentry keeps your SDS library, GHS labels and HazCom training records in one place — $24 per location a month, or $199 a year, with unlimited users.

Unlimited users and no SDS cap. On an annual plan that is less than any paid SDS tool we compared.

Start 7-day free trial Compare SDS software prices →