Propylene Glycol SDS: What a USP Propylene Glycol Sheet Says
📄 Get the SDS: BASF 1,2-Propylene Glycol USP SDS, version 6.1, Jun 2025
Short answer: BASF’s SDS for 1,2-Propylene Glycol USP (version 6.1, revised June 25, 2025), written to the 2024 HazCom standard, says there is "no need for classification according to GHS criteria" and the product "does not require a hazard warning label". Its flash point is 104 °C (closed cup). Glycol sold for chillers is often an inhibited blend from another supplier with its own sheet, so check what is in your tank.
Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.
What the propylene glycol SDS covers
We read BASF’s US sheet, checked October 20, 2026:
- Classification: not classified; no hazard warning label required.
- Composition: propylene glycol (CAS 57-55-6), at least 99.95%.
- Properties (Section 9): colorless, odorless liquid; pH 4–7; boiling point 184 °C; flash point 104 °C (219 °F), closed cup, "not readily ignited"; autoignition above 400 °C.
- Exposure limits (Section 8): "No substance specific occupational exposure limits known."
- Incompatible (Section 10): zinc and strong oxidizing agents; avoid temperatures above 40 °C, humidity and daylight.
Chiller glycol: check which product is in the tank
Brewery and winery chillers usually circulate a propylene glycol and water mix, often bought as a pre-blended, inhibited heat-transfer fluid. Corrosion inhibitors and dyes can change the classification, so the USP sheet above covers only pure propylene glycol: keep the sheet from the company that sold your blend. Automotive antifreeze is usually ethylene glycol, a different chemical with a different SDS (see antifreeze SDS). Where a refrigeration system uses ammonia rather than glycol, that is a separate hazard with its own OSHA requirements and is outside this page.
A chemical that is not hazardous under HazCom does not need an SDS on file, but many breweries keep this one so the binder matches the inventory and so a glycol leak or spill can be answered quickly.
PPE and handling the sheet calls for
- Eyes: safety glasses with side shields.
- Hands: chemical-resistant gloves, selected on the user’s assessment of the workplace hazards.
- Air: ensure thorough ventilation; local exhaust where vapors or mists form, as from a hot or sprayed glycol leak.
- Spills: prevent discharge into the environment; pump off larger amounts. A glycol spill on a cellar floor is a slip hazard.
First aid (Section 4)
- Eyes: wash for at least 15 minutes under running water with eyelids held open.
- Skin: wash thoroughly with soap and water.
- Swallowed: rinse mouth and drink 200–300 ml of water. In the United States, Poison Control is 1-800-222-1222.
- Inhaled: keep calm and move to fresh air.
Storage
Keep the container tightly closed and dry, in a cool place no warmer than 40 °C (104 °F), protected from air, humidity and light, and away from oxidizers. See chemical storage compatibility.
Where to get the current propylene glycol SDS
- The sheet we read: BASF 1,2-Propylene Glycol USP SDS, version 6.1, Jun 2025, checked October 20, 2026.
- Your supplier must provide the SDS with the first shipment (29 CFR 1910.1200(g)(6)–(7)), and the manufacturers below publish theirs free online. Or search for a propylene glycol SDS with our free SDS search.
Where it fits in a brewery, winery or distillery HazCom program
Your chiller glycol belongs on your chemical inventory, and its SDS belongs where cellar, packaging and production staff can reach it during every shift (29 CFR 1910.1200(g)(8)). Train people on it before they use it, and again when a new hazard comes in, such as a new supplier or formula (1910.1200(h)(1)). Buckets, spray bottles and CIP make-up tanks filled from the drum need a workplace label unless they are only for the immediate use of the person who filled them: the free GHS label maker prints them from the hazard classes above (see secondary container labeling). Keep acids, caustics and oxidizers apart (chemical storage compatibility), and see the OSHA requirements for breweries and wineries and the printable brewery SDS binder checklist.
Frequently asked questions
Is propylene glycol hazardous under OSHA?
BASF's SDS for 1,2-Propylene Glycol USP (June 2025) says it needs no classification under GHS criteria and requires no hazard warning label. Inhibited glycol blends sold for chillers can differ, so check the sheet for the exact product.
What is the flash point of propylene glycol?
The BASF sheet gives 104 C (219 F), closed cup, and describes it as not readily ignited.
Does propylene glycol have an OSHA PEL?
No. The BASF SDS says no substance-specific occupational exposure limits are known.
Do I need an SDS for chiller glycol?
HazCom requires SDSs for hazardous chemicals. Pure USP propylene glycol is not classified, but an inhibited blend may be, so keep the sheet from the company that sold your glycol.
Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →
SDSentry keeps your SDS library, GHS labels and HazCom training records in one place — $24 per location a month, or $199 a year, with unlimited users.
Unlimited users and no SDS cap. On an annual plan that is less than any paid SDS tool we compared.
Start 7-day free trial Compare SDS software prices →