Funeral Home HazCom and Formaldehyde Checklist (Printable)
How to use it: print this page (the button below hides the site navigation), walk the preparation room, supply storage, chapel and janitorial areas, and tick each item. Each item is tied to the paragraph of the OSHA standard it comes from, checked October 10, 2026 against eCFR. The full explanation is in OSHA requirements for funeral homes.
Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.
Funeral home / location: ______________________ Checked by: ______________ Date: __________
Formaldehyde (29 CFR 1910.1048)
- Initial monitoring done for embalming staff, or objective data on file showing exposure cannot reach the 0.5 ppm action level or 2 ppm STEL ((d)(1)–(2), (o)(2)).
- Periodic monitoring on schedule where results were at or above the action level (every 6 months) or STEL (yearly) ((d)(3)); employees told results within 15 working days ((d)(6)).
- Ventilation and work practices keep exposure at or below 0.75 ppm TWA and 2 ppm STEL ((c), (f)).
- Impervious gloves, aprons and goggles or face shields for fluids of 1% formaldehyde or more ((h)(1)(i)).
- Eyewash within the immediate work area ((i)(3)) and a quick drench shower where skin may be splashed with 1%+ solutions ((i)(2)); both tested and unobstructed.
- Leak and spill inspections and emergency procedures in place ((j), (k)).
- Medical surveillance offered where required ((l)).
- Formaldehyde training given at initial assignment and within the last 12 months ((n)(2)).
- Respirator program under 1910.134 if respirators are required ((g)).
HazCom inventory and SDSs (1910.1200(e), (g))
- Every arterial fluid, cavity fluid, pre- and co-injection chemical, disinfectant, solvent, adhesive, sealer, cosmetic and cleaning product listed by the name on its SDS.
- A current manufacturer SDS for each, including formaldehyde products ((m)(1)(iii) of 1910.1048).
- Sheets reachable in the preparation room on every shift, including night removals, without barriers ((g)(8)).
- Written HazCom program with the chemical list, available to employees.
Labels and training (1910.1200(f), (h))
- Original containers keep legible manufacturer labels; decanted and diluted containers labelled with product identifier and hazards ((f)(6)). Free: GHS label maker.
- Every exposed employee trained at initial assignment and when a new chemical hazard is introduced; records kept ((h)(1)).
- Labels, program and training updated for the revised standard (substances by November 20, 2026).
Bloodborne pathogens and general (not HazCom)
- Exposure control plan reviewed in the last 12 months; HBV vaccination offered; annual BBP training (1910.1030).
- Written PPE hazard assessment certified (1910.132(d)).
- OSHA "It’s the Law" poster displayed (1903.2).
Related: formalin SDS, methanol SDS, glutaraldehyde SDS, eyewash station requirements, SDS software for funeral homes.
Other healthcare offices
The same HazCom duties apply across healthcare offices; each guide covers what is different for that practice type: dental offices, oral surgery and orthodontic offices, medical offices and urgent care, med spas and aesthetic clinics, optometry and eye care offices, veterinary clinics, funeral homes and tattoo studios.
Frequently asked questions
What should a funeral home OSHA checklist include?
Formaldehyde monitoring or objective data, controls, PPE, eyewash and drench shower, medical surveillance and annual formaldehyde training under 29 CFR 1910.1048; a HazCom inventory, SDSs, labels, written program and training under 29 CFR 1910.1200; and a bloodborne pathogens exposure control plan under 29 CFR 1910.1030.
Is formaldehyde training required every year?
Yes. 29 CFR 1910.1048(n)(2) requires formaldehyde training at initial assignment, when a new exposure is introduced, and at least annually, unless objective data show employees are not exposed at or above 0.1 ppm.
Do embalming fluids need safety data sheets?
Yes. They are hazardous chemicals, and the formaldehyde standard requires formaldehyde products to be in the HazCom program with labels and SDSs. Keep the manufacturer SDS for each fluid you use.
Can formaldehyde monitoring ever stop?
Periodic monitoring may stop when two consecutive sampling periods at least 7 days apart show exposure below both the action level and the STEL, under 29 CFR 1910.1048(d)(4).
Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →
SDSentry keeps your SDS library, GHS labels and HazCom training records in one place — $24 per location a month, or $199 a year, with unlimited users.
Unlimited users and no SDS cap. On an annual plan that is less than any paid SDS tool we compared.
Start 7-day free trial Compare SDS software prices →