Eyewash Station Inspection Checklist & Weekly Log

⏰ OSHA HazCom deadline — November 20, 2026: employers must update their workplace labels, written HazCom program, and employee training to the new GHS format by then. Check your program free — 2-minute self-audit →
Published October 10, 2026 · Sources checked October 10, 2026

Short answer: this page gives you two free printables — a one-page inspection checklist and a weekly activation log — for emergency eyewash stations. Each checklist item is marked as either an OSHA requirement or an Z358.1 practice. That distinction matters: OSHA's rule, 29 CFR 1910.151(c), requires suitable flushing facilities but does not set a testing schedule. The weekly activation and annual inspection come from the consensus standard ANSI/ISEA Z358.1, which OSHA refers employers to for guidance. For when a station is required in the first place, and the access and flushing rules, see emergency eyewash and safety shower requirements.

⬇ Download the PDF (checklist + 52-week log)

The PDF is three US Letter pages: the inspection checklist, then weeks 1–26 and 27–52 of the activation log. Print one log per unit. Free, no signup.

1. Eyewash station inspection checklist

OSHA = required by the regulation itself. Z358.1 = from the ANSI/ISEA Z358.1 consensus standard, as ISEA publicly summarizes it; OSHA does not enforce Z358.1 as a standard, but may refer to it when judging whether facilities are “suitable”. Mfr = follow the manufacturer’s instructions.

A. Is a station required, and is it there?

B. Access, signage and location

C. Function

D. Maintenance and records

E. Training

Print one sheet per unit, or download the PDF for a full year (52 weeks). For self-contained units, use the notes column for the fluid’s expiry or replacement date.

Location / area:
Unit ID:
Month / quarter / year:
Unit type: Plumbed Self-contained Drench hose Combination
WeekDateInitialsFlushed clear
Y / N
Notes / corrective action
1Y  /  N
2Y  /  N
3Y  /  N
4Y  /  N
5Y  /  N
6Y  /  N
7Y  /  N
8Y  /  N
9Y  /  N
10Y  /  N
11Y  /  N
12Y  /  N
13Y  /  N

Annual inspection completed (date / by): ______________________   Reviewed by: ______________________

3. The legal basis, stated carefully

The regulation. 29 CFR 1910.151(c) reads, in full: “Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.” That sentence is the whole federal requirement. It says nothing about weekly testing, annual inspections, distances, temperatures or flushing time.

Where the schedule comes from. Weekly activation and annual inspection are practices from ANSI/ISEA Z358.1, the consensus standard for emergency eyewash and shower equipment. OSHA has said plainly that it has not adopted Z358.1 and does not enforce it, but that it “has often referred employers to ANSI Z358.1 as a recognized source of guidance” and would take it into consideration when evaluating the adequacy of protection. If facilities are unsuitable, OSHA cites 1910.151(c) itself, and in deciding suitability it “may refer to the most recent consensus standard.” So a missing weekly log is not, by itself, a violation of a numbered OSHA rule — but a clogged, empty, blocked or untested unit is the kind of evidence that makes a facility unsuitable, and the log is how you show yours is not.

Edition. ISEA’s site lists ANSI/ISEA Z358.1-2014 (R2020) as the standard. The figures on this page (10 seconds / about 55 feet, 15 minutes, tepid 60–100°F, 1-second valve, 0.4 gpm) are as ISEA publicly summarizes that edition; we do not reproduce the standard’s text. Mounting heights, nozzle and spray-pattern dimensions and test-gauge procedures are per ANSI/ISEA Z358.1; check the current edition. Some State Plan states and local plumbing codes add their own rules.

Sources (checked October 10, 2026)

4. How SDSentry helps

SDSentry does not log eyewash activations — use the sheet above for that. What it does is the chemical side that decides whether you need a station and whether your people know what to do:

Educational information, not legal or compliance advice. ANSI/ISEA Z358.1 is a consensus standard OSHA refers employers to for guidance under 29 CFR 1910.151(c); OSHA has not adopted it, and it is periodically revised. Confirm the current edition, follow your equipment manufacturer’s instructions, and consult a qualified safety professional for your workplace.

Start with the chemical list
A HazCom program starts from a list of the hazardous chemicals at your site. Download the free chemical inventory list template as a CSV for Excel or Google Sheets, or as a printable PDF. Free, no signup.
Get the free chemical inventory template →

Frequently asked questions

Does OSHA require weekly eyewash station testing?

Not in its own words. OSHA's rule, 29 CFR 1910.151(c), requires suitable facilities for quick drenching or flushing of the eyes and body within the work area for immediate emergency use where the eyes or body of any person may be exposed to injurious corrosive materials. It does not set a testing schedule. Weekly activation of plumbed units and an annual inspection of all units come from the consensus standard ANSI/ISEA Z358.1. OSHA has not adopted Z358.1, but its letters of interpretation say it has often referred employers to Z358.1 as a recognized source of guidance and may refer to the most recent consensus standard when judging whether facilities are suitable.

How often should an eyewash station be inspected?

Under ANSI/ISEA Z358.1, as summarized in ISEA's public selection and use guide: plumbed units are activated weekly, long enough to verify operation and flush stagnant water from the supply line; self-contained units are visually inspected per the manufacturer's instructions to see whether the flushing fluid needs changing; and every unit gets a full inspection at least annually, with results recorded. Check the current edition of the standard and your manufacturer's instructions.

What should an eyewash station inspection log include?

The unit's location and type (plumbed, self-contained, drench hose or combination), the week or date of each activation, the initials of the person who did it, whether the water ran clear, and any problem found with the corrective action taken. For self-contained units, record the flushing fluid's expiry or replacement date. Keep the annual inspection record alongside the weekly log.

Do self-contained eyewash stations need weekly activation?

Weekly activation is the Z358.1 practice for plumbed units, where its purpose is to clear stagnant water from the supply line. Self-contained units are instead visually inspected and their flushing fluid changed or supplemented as the manufacturer's instructions specify, and they are included in the annual inspection. Follow the manufacturer's schedule and replace the fluid before its expiry date.

Is a drench hose a substitute for an eyewash station?

Generally not. ISEA's guide describes a drench hose as a supplemental device that supports a compliant eyewash or drench shower but does not replace it, unless the drench hose itself contains an eye or eye/face wash that meets all the Z358.1 performance requirements.


Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →