Oxygen SDS: What the Safety Data Sheet Says
📄 Get the SDS: Airgas oxygen SDS 001043 (PDF)
Short answer: Airgas’s SDS for oxygen (SDS 001043, version 5.06, 28 March 2025, covering Oxygen USP among its synonyms) classifies it as an Oxidizing Gas Category 1 and a compressed gas under pressure, signal word Danger: "May cause or intensify fire; oxidizer" and "Contains gas under pressure; may explode if heated". It has no exposure limit; the hazards are fire and the cylinder.
Free, no signup: the SDS binder builder at sdsentry.0xpi.com/sds-binder.html turns a pasted list of the products you keep on site into one printable index of their current safety data sheets.
What the oxygen SDS covers
We read Airgas’s sheet for oxygen, SDS 001043 (date of revision 3/28/2025), checked October 10, 2026:
- Classification (Section 2): Oxidizing gases Category 1; Gases under pressure, compressed gas. The sheet states it is hazardous under 29 CFR 1910.1200.
- Hazard statements: H270 "May cause or intensify fire; oxidizer"; H280 "Contains gas under pressure; may explode if heated".
- Pictograms: under GHS these classes carry the flame over circle (oxidizer) and gas cylinder.
- Precautions: keep away from clothing and other combustible materials (P220); keep reduction valves, valves and fittings free from oil and grease (P244); use only equipment cleaned for oxygen service; open valves slowly; close the valve after each use and when empty.
- Exposure limits (Section 8): none.
- Fire (Section 5): oxidizing material that increases the risk of fire; contact with combustible material may cause fire; a heated cylinder may burst or explode.
Cylinder storage and handling
The sheet says to store cylinders in a segregated and approved area, away from direct sunlight, in a dry, cool, well-ventilated place, upright, with the valve protection cap in place, firmly secured so they cannot fall, separated from reducing agents and combustible materials, away from grease and oil, and never above 52 °C (125 °F). Do not drag, roll, slide or drop cylinders; use a hand truck. In a clinic that means chained or racked E and H cylinders, a full/empty system, and no cleaning chemicals, oily rags or paper stock stored against the cylinders.
OSHA’s compressed gas rule, 29 CFR 1910.101, requires employers to determine by visual inspection that cylinders under their control are in a safe condition, and sets in-plant handling and storage by Compressed Gas Association Pamphlet P-1.
First aid (Section 4)
- Frostbite from contact with rapidly expanding gas: warm the frozen tissue and seek medical attention.
- Eyes: flush with plenty of water, lifting the eyelids; get medical attention.
- Inhaled: remove to fresh air and keep at rest.
Where to get the right oxygen SDS
The Airgas sheet lists synthetic/analytical chemistry as its product use and names Oxygen USP among its synonyms. Keep the SDS from the company that fills your cylinders, matched to the product on your invoice.
- Reference sheet: Airgas oxygen SDS 001043 (PDF), checked October 10, 2026.
- Your supplier must provide the SDS with the first shipment (29 CFR 1910.1200(g)(6)–(7)); veterinary distributors usually also post it on the product page. Or search for an oxygen SDS with our free SDS search.
Where it fits in a veterinary clinic HazCom program
Oxygen belongs in your clinic’s SDS binder or digital SDS library, on your chemical inventory, and in the HazCom training you give every veterinarian, technician, assistant, kennel attendant and front-desk hire before they handle it. If you decant or dilute it, label the new container: the free GHS label maker prints secondary-container labels from the hazard classes above. See OSHA requirements for veterinary clinics, the veterinary clinic SDS binder list and the printable veterinary HazCom checklist.
Frequently asked questions
Is oxygen a hazardous chemical under OSHA HazCom?
Yes. Airgas's oxygen SDS classifies it as an Oxidizing Gas Category 1 and a compressed gas under pressure, with the signal word Danger, and states it is hazardous under 29 CFR 1910.1200.
Why must oxygen fittings be kept free of oil and grease?
Oxygen is an oxidizer that may cause or intensify fire, so the SDS says to keep reduction valves, valves and fittings free from oil and grease and to use equipment cleaned for oxygen service.
How should oxygen cylinders be stored in a veterinary clinic?
Upright, firmly secured, with the valve cap on, in a segregated, dry, cool, well-ventilated area out of direct sunlight, away from combustibles, grease and oil, and below 52 C (125 F), per the Airgas SDS.
Is there an exposure limit for oxygen?
No. The Airgas SDS lists no occupational exposure limit; the hazards are fire and pressure.
Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →
SDSentry keeps your SDS library, GHS labels and HazCom training records in one place — $24 per location a month, or $199 a year, with unlimited users.
Unlimited users and no SDS cap. On an annual plan that is less than any paid SDS tool we compared.
Start 7-day free trial Compare SDS software prices →