Guides / NFPA 704 Diamond Explained

NFPA 704 Diamond Explained: The Four Colors, the 0–4 Ratings and the Special Symbols

⏰ OSHA HazCom 2024 deadline — November 20, 2026 (substances): employers must, as necessary, update workplace labels, the written HazCom program and employee training for newly identified hazards. For mixtures the date is May 19, 2028 (29 CFR 1910.1200(j)). Check your program free — 2-minute self-audit →
Free tool: make and print a GHS label for a secondary container — tick the hazard classes from the SDS and it fills in the signal word, pictograms and hazard statements. No signup.
Published October 10, 2026 · Sources checked October 10, 2026

Short answer: the NFPA 704 “fire diamond” rates a material for health (blue, left), flammability (red, top) and instability (yellow, right) on a scale from 0 (minimal hazard) to 4 (severe hazard), with special hazards (white, bottom) such as W, OX and SA. It is written for emergency responders at fixed facilities. The GHS label that OSHA requires on chemical containers counts the other way — Category 1 is the most severe — so an NFPA 4 and a GHS Category 1 can describe the same extreme hazard. Never copy one number into the other system.

NFPA 704 diamond layout: health 2 on blue at left, flammability 4 on red at top, instability 0 on yellow at right, W in the white special-hazard quadrant at bottom 4 2 0 W

Health — nine o’clock

Flammability — twelve o’clock

Instability — three o’clock

Special hazards — six o’clock

Example values are the fictional “NOMIXUP 7042012” teaching substance from the joint NFPA/OSHA quick card, not a real product.

What NFPA 704 is

NFPA 704 is the National Fire Protection Association’s Standard System for the Identification of the Hazards of Materials for Emergency Response. NFPA describes it as a simple, readily recognized system of markings that gives an immediate general sense of a material’s hazards and how severe they are as they relate to emergency response. The current edition listed on NFPA’s site is the 2027 edition. NFPA publishes the standard itself; this guide describes only what NFPA and OSHA say about it publicly, so check the current edition for the rating criteria.

The four quadrants

The 0–4 scale

Health, flammability and instability each get a number from 0, indicating a minimal hazard, to 4, indicating a severe hazard. Higher is worse. The exact criteria for each number (for example, the flash-point bands behind each flammability rating) are set out in the rating tables of the standard — check the current edition rather than a poster or a third-party summary.

The special hazard symbols: W, OX and SA

NFPA’s own explanation lists three special hazard symbols in use:

You will sometimes see other marks in the white quadrant on commercial signs. They are not among the three special hazard symbols NFPA lists; check the current edition before relying on one.

The key confusion: NFPA 4 is the worst, GHS Category 1 is the worst

The numbers run in opposite directions. On the NFPA diamond, 0 is the least hazardous and 4 the most. Under OSHA’s Hazard Communication Standard, GHS hazard categories run from 1, the most severe, downward (the NFPA/OSHA card puts it as “1 — most severe hazard, 4 — least severe hazard”). In the card’s worked example, a substance classified as Flammable Gas, Category 1 gets a 4 in the red flammability quadrant.

There is a second difference that matters as much as the direction. A GHS category number is a classification that decides which pictogram, signal word and hazard statements go on the label. OSHA does not require the category number on the label at all; it appears in Section 2 of the safety data sheet. The NFPA number is the message on the placard. So a worker who sees “Category 1” on an SDS and “1” on a diamond is looking at opposite ends of two different scales.

Do not work out NFPA numbers from GHS categories yourself

The NFPA/OSHA comparison card says it directly: the hazard category numbers in Section 2 of a HazCom 2012 SDS are not to be used to fill in the NFPA 704 diamond. The two systems use different criteria — NFPA health ratings, for instance, ignore chronic effects that drive GHS health classifications — so there is no reliable one-to-one conversion. The card’s route is:

  1. Check whether the supplier’s SDS already gives NFPA ratings (many do; see below).
  2. If not, collect the data from the SDS: Section 11 for health, Section 9 for flammability, Section 10 for instability, and Sections 9–11 for special hazards.
  3. Compare that data with the rating criteria in the current edition of NFPA 704, and assign the numbers.

If nobody on site can do step 3 confidently, ask the supplier, your fire marshal or a qualified safety professional. A wrong number on a placard misleads the people who rely on it most.

Where NFPA ratings appear on a safety data sheet

They are optional. OSHA’s HazCom FAQ says NFPA and HMIS information is not required on SDSs but may be included if it does not contradict or cast doubt on the HazCom classification, and a 2014 OSHA letter of interpretation confirms they may appear in Section 2. In practice, when we checked the 227 supplier SDSs in SDSentry’s shared library on October 10, 2026, roughly a third showed NFPA ratings, and where they did, they were usually in Section 16 (Other information), occasionally in Section 2 or Section 5 (fire-fighting measures). That library reflects the products our customers keep, so treat it as a pattern, not a rule. For what each section holds, see the 16 sections of a safety data sheet.

Who uses NFPA 704 and who uses GHS labels

NFPA 704 diamondGHS label (OSHA HazCom)
AudienceEmergency responders to a fire or spill, and people planning emergency responseWorkers handling the chemical under normal use and foreseeable emergencies
WhereFixed facilities: building entrances, room and storage-area doors, tanks and some containers. Not for transportationEvery container of a hazardous chemical, shipped or in the workplace
When requiredOnly when another code, regulation or the authority having jurisdiction requires it (NFPA names NFPA 1, NFPA 30, NFPA 55 and NFPA 400 as widely used codes that do)Always, under 29 CFR 1910.1200(f)
Numbers0–4, 4 most severe, printed on the placardCategories from 1 (most severe); used to classify, not printed on the label
Health hazardsAcute onlyAcute and chronic (for example carcinogens)
What it showsFour ratings and any special symbolProduct identifier, signal word, hazard statements, pictograms, precautionary statements, supplier details

NFPA’s public guidance says placards should be visible where responders are likely to enter, and points to section 4.3 of the standard for the minimum locations, which include two exterior walls and each access to a room or area. Your fire marshal decides what is required locally.

Can an NFPA diamond satisfy OSHA workplace labeling?

Partly, and only inside your own workplace. The workplace-labeling rule, 29 CFR 1910.1200(f)(6), lets an employer label a workplace container either with the full shipped-container label or with the product identifier plus “words, pictures, symbols, or combination thereof” that give at least general information about the hazards and, together with the other information available to employees, provide the specific hazard information. OSHA’s HazCom FAQ says NFPA 704 and HMIS are permitted for workplace containers on these conditions:

Because NFPA 704 rates acute health hazards only, a carcinogen or other chronic hazard needs to reach employees another way — words on the label, the SDS and training. And the diamond never replaces the full GHS label on a container that leaves your workplace. An NFPA technical services engineer, writing on NFPA’s site in 2025, puts the limit plainly: the diamond is used in fixed facilities and on its own does not meet OSHA Hazard Communication or DOT requirements. For the simplest compliant option on a spray bottle or jug, use a GHS-style label — see secondary container labeling under GHS, or compare the other color-bar system in HMIS labels vs GHS.

How the diamond relates to the GHS pictograms

The diamond and the GHS pictograms are both square-on-point shapes, which is part of the confusion. A GHS pictogram is a black symbol on white inside a red frame; there are nine, and OSHA requires eight. Print the one-page GHS pictograms chart to post next to your SDS binder, or read GHS pictograms explained for what each symbol means. The complete list of what a shipped label must carry is in GHS label requirements.

Sources (checked October 10, 2026)

How SDSentry helps

SDSentry does not assign NFPA ratings — that takes the standard and someone qualified to apply it. It keeps the inputs in one place: each location’s current supplier SDSs (including any NFPA or HMIS ratings the supplier printed), a chemical inventory your fire marshal can read, GHS labels printed from each product’s hazard data, and training records showing staff were taught what the labels mean.

Try SDSentry free for 7 days

Educational information only, not legal or compliance advice. NFPA 704 is a copyrighted NFPA standard; this page describes it from NFPA’s public pages and does not reproduce its text. Confirm placard requirements with your fire marshal and current requirements at osha.gov/hazcom.

Labeling a spray bottle or secondary container?
The free GHS label maker prints a label with the product name, pictograms, signal word and hazard statements you choose. Free, no signup.
Make a free GHS label →

📋 Could you produce the sheet for every product on your shelf?
Paste the products you keep on site and get each product’s safety data sheet laid out as one printable binder index — the thing an inspector asks to see. Free, no signup, nothing emailed to you.
Build my SDS binder — free →
Just one product? Free SDS search. Want to know where your site stands against 29 CFR 1910.1200? 2-minute HazCom self-audit. No signup for either.

Frequently asked questions

What do the colors on the NFPA diamond mean?

Blue (left, nine o'clock) is health, red (top, twelve o'clock) is flammability, yellow (right, three o'clock) is instability, and white (bottom, six o'clock) is for special hazards. Health, flammability and instability are each rated from 0, a minimal hazard, to 4, a severe hazard.

Is 4 or 1 the most dangerous on an NFPA diamond?

On an NFPA 704 diamond, 4 is the most severe rating and 0 the least. GHS hazard categories under OSHA's Hazard Communication Standard run the other way: Category 1 is the most severe category in a hazard class. A chemical in Flammable Gas Category 1 can carry a 4 in the red flammability quadrant, so the two numbers must never be swapped for each other.

What do W, OX and SA mean on an NFPA diamond?

They are the special hazard symbols used in the white bottom quadrant. W means the material reacts with water in an unusual or dangerous way, a caution about using water in firefighting or spill control. OX means oxidizer. SA means simple asphyxiant gas, such as nitrogen, helium, neon, argon, krypton or xenon, which can displace oxygen.

Can an NFPA diamond be used as an OSHA workplace label?

For containers used inside your own workplace, OSHA says NFPA 704 and HMIS ratings are permitted, with conditions: the container still needs the product identifier, the label must give at least general information about the hazards, it may not show hazard warnings or pictograms that conflict with the HazCom classification, and employees must be trained to understand the system. Because NFPA 704 covers only acute hazards, chronic effects such as cancer have to be conveyed some other way. A diamond does not replace the full GHS label on shipped containers.

Where are NFPA ratings on a safety data sheet?

They are optional. OSHA does not require NFPA or HMIS ratings on an SDS but allows them if they do not contradict or cast doubt on the HazCom classification. In the supplier SDSs we checked, the ratings, where present, were usually in Section 16 (Other information), and occasionally in Section 2 or Section 5.

Can I work out NFPA ratings from the GHS categories on the SDS?

No. The NFPA and OSHA comparison quick card says the hazard category numbers in Section 2 of a HazCom 2012 SDS are not to be used to fill in the NFPA 704 diamond. NFPA ratings are assigned from the criteria in the standard, using data such as Section 9 (flammability), Section 10 (instability) and Section 11 (health). If the SDS does not give the ratings, ask the supplier or a qualified person using the current edition of NFPA 704.


Most SDS software stops at the safety data sheets. OSHA HazCom asks an employer for five things: a written program, a chemical list, container labels, SDS access and employee training. SDSentry covers all five in one product and builds the written program from your own chemical list. See how 11 SDS tools compare on all five →

SDSentry keeps your SDS library, GHS labels and HazCom training records in one place — $24 per location a month, or $199 a year, with unlimited users.

Unlimited users and no SDS cap. On an annual plan that is less than any paid SDS tool we compared.

Start 7-day free trial Compare SDS software prices →
Free for your site: add a live OSHA HazCom 2026 deadline countdown — one line of HTML, no sign-up. Get the free widget →